Biddle CA2 Especificaciones Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Materials, Components &
Specifications
Control & Operation
The b-touch control panel regulates air volume, air velocity, discharge width
and temperature in either automatic or manual mode. It is connected to the
unit by a low-voltage data cable with RJ11 plugs. Multiple units are also connected
in this way.
Electric Connections
LPHW heated units are connected to the mains supply by a 2 metre cable with a
moulded, earthed plug.
The mains supply cable on electric heated units enters the air curtain via a cable
gland on the top of the unit. The cable is then connected to a terminal strip within
the unit. The water connections and low voltage connector plate are fitted to the
top of the unit to avoid the need for opening during installation.
Casing
The casing is made from zinc plated sheet steel and incorporates an inspection
panel. The inlet grilles have anodised aluminium grilles with fixed fins.
All casing components come in two standard colours - white (RAL 9016) or silver
aluminium (RAL 9006). Other RAL colours are available at an additional charge.
Motor/Fan Assembly
Units are supplied with two or more (depending on type) dual-inlet, vibration-free
suspended centrifugal fans driven b
y a two-side, suspended rotor motor. The fan
casing and impeller are made from zinc coated steel.
The motor is manufactured according to DIN 40050, protection class IP44 and
insulation class B. It is fitted as standard with thermal contacts which break the
circuit if the maximum motor temperatur
e is e
xceeded.
LPHW Heating Battery
The heating battery comprises copper pipes and aluminium fins and a water supply
connection with a G1”
female thr
ead.
The test pressure is 30 bars and the maximum operating pressure is 6 bars at
110°C.
Electric Heating Battery
The electric heating battery is made from aluminium fins and incorporates an
electronic control unit, complete with overload protection. When the unit is
switched off, the fans will continue to rotate until the fins have sufficiently cooled.