The CA
2
air curtain is as a standard suitable for all water ranges from 45/35 °C to 90/70°C.
1
Dependingonthesituationtheoutlettemperaturevariesinallspeedsbetween20°Cand50°Cmax.
2
Basedonalimitedairoutlettemperatureof50°C.
3
Basedonawaterrangeof60/40°C.
Basic data:
•doorwidth : 150cm
•roomtemperature : 20ºC
•airoutlettemperature
1
: speed1-5=35°C
speed6 =40°C
•powersupply :W=230V/E=400V
*Seetableonpage10.
Technical data CA
2
S/M/L/XL - 150
13
CA
2
S-150
Water
Electric
door height*
weight model F/R/C
max. heating capacity
2
water flow rate
3
water pressure loss, incl. valve
3
max. power, motors
max.current,motors(1phase)
max. power consumption, heating
max.currentconsumption(3phases)
cm
kg
kW
l/h
kPa
kW
A
kW
A
200 - 240
65/87/82
17.4
430
2.18
0.28
1.27
-
-
70/92/87
14.8
-
-
0.28
1.27
15.6
23.8
Speed 1 2 3 4 5 6
air displacement
heating capacity
noise level at 3 m
m
3
/h
kW
dB(A)
630
3.2
29
880
4.4
37
1010
5.1
40
1310
6.6
45
1525
7.7
49
1730
11.6
52
CA
2
M-150
Water
Electric
door height*
weight model F/R/C
max. heating capacity
2
water flow rate
3
water pressure loss, incl. valve
3
max. power, motors
max.current,motors(1phase)
max. power consumption, heating
max.currentconsumption(3phases)
cm
kg
kW
l/h
kPa
kW
A
kW
A
220 - 280
74/96/91
23.7
530
3.20
0.40
1.86
-
-
79/101/96
19.8
-
-
0.40
1.86
20.8
33.8
Speed 1 2 3 4 5 6
air displacement
heating capacity
noise level at 3 m
m
3
/h
kW
dB(A)
740
3.7
28
1095
5.5
38
1320
6.6
43
1790
9.0
49
2140
10.7
52
2365
15.8
55
CA
2
L-150
Water
Electric
door height*
weight model F/R/C
max. heating capacity
2
water flow rate
3
water pressure loss, incl. valve
3
max. power, motors
max.current,motors(1phase)
max. power consumption, heating
max.currentconsumption(3phases)
cm
kg
kW
l/h
kPa
kW
A
kW
A
250 - 330
96/121/118
49.5
1036
4.47
1.00
4.55
-
-
104/129/126
34.6
-
-
1.00
4.55
36.4
56.3
Speed 1 2 3 4 5 6
air displacement
heating capacity
noise level at 3 m
m
3
/h
kW
dB(A)
1715
8.6
39
2260
11.3
44
2830
14.2
48
3645
18.3
54
4295
21.6
57
4930
33.0
60
CA
2
XL-150
Water
Electric
door height*
weight model F/R/C
max. heating capacity
2
water flow rate
3
water pressure loss, incl. valve
3
max. power, motors
max.current,motors(1phase)
max. power consumption, heating
max.currentconsumption(3phases)
cm
kg
kW
l/h
kPa
kW
A
kW
A
300 - 380
102/127/124
59.9
1162
5.50
1.67
7.53
-
-
110/135/132
34.6
-
-
1.67
7.53
36.4
59.0
Speed 1 2 3 4 5 6
air displacement
heating capacity
noise level at 3 m
m
3
/h
kW
dB(A)
2055
10.3
45
2725
13.7
49
3440
17.3
53
4465
22.4
58
5300
26.6
62
5970
40.0
65